972-A
- Fuse Holder
- Maximum Insulation 0.150″ (3,81)
- Wire Range 18-14 (0.75-1.5)
- Temperature 105*C (221*F)
557*
- Dual Element Connection
- Flame Retardant
- Maximum Insulation 0.155″ (3,94)
- Wire Range 22-16 (0,5-1,5)
- Temperature 105*C (221*F)
558*
- Flame Retardant
- Maximum Insulation 0.155″ (3,94)
- Wire Range 22-16 (0,5-1,5)
- Temperature 105*C (221*F)
560
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 105*C (221*F)
560B
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 105*C (221*F
560N
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 105*C (221*F)
562
- Run & Tap Splicing Flame Retardant
- Maximum Insulation 0.190″ (4.82 mm)
- Wire Range 12-10 (3,0-4.0)
- Solid/Standard 10 standard
- Temperature 90*C (194*F)
567
- Dual Element Connection
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm) Tap & 0.190" (4.82mm) Run
- Wire Range 18-14 (0,75-1,5) Tap & 12-10 (3.0-4.0) Run
- Temperature 105*C (221*F)
564
- Dual Element Connection
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm) TapÂ
- Wire Range 18-14 (0,75-1,5)Â
- Temperature 90*C (194*F)
804
- Moisture Resistant ApplicationsÂ
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 75*C (167*F)
901
- Disconnect
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Temperature 90*C (194*F)
905
- Low Voltage (Automotive) ApplicationsÂ
- Maximum Insulation 0.110" (2.79 mm) Tap & 0.145" (3.68 mm) Run
- Wire Range 22-18 (0.5-1.0) Tap & 18-14 (0.75-1.5) Run
- Temperature 90*C (194*F)
905N
- Low Voltage (Automotive) ApplicationsÂ
- Maximum Insulation 0.110" (2.79 mm) Tap & 0.145" (3.68 mm) Run
- Wire Range 22-18 (0.5-1.0) Tap & 18-14 (0.75-1.5) Run
- Temperature 90*C (194*F)
3M BBI-A Busbar Sleeves
Get durable and reliable protection that helps prevent failures and downtime in applications from 5-25 kV. 3Mâ„¢ Heat Shrinkable Bus Bar Tubing BBI-3A covers and insulates rectangular, square or round bus bars, and resists splitting and solvents.
3M CCI Tubes
66kv/72.5kv Termination
110kv(123kv)/132kv (145kv) Termination
66kv/72.5kv Splice
110kv(123kv) / 132kv (145kv) Splice
Special Contact Cleaner 1625 Spray
- Loosens dirt, light oxide layers, and impurities of every kind in
an effective gentle manner. - Electrically neutral and totally residue-free
Multi Five 1640 Spray
3M FireDam 240
Large electrical and mechanical through penetrations can be sealed to provide up to 4 hours fire rating using 3Mâ„¢ FireDamâ„¢ 2000 Coating applied on mineral fiber board known as 3M FireDamâ„¢ 240 Coated Mineral Board. In the presence of heat or fire, the coating on top of 3Mâ„¢ FireDamâ„¢ 240 intumesces (expands) up to 10 times, forming an insulating char which significantly slows any heat transfer. The expanding char fills voids,including those left by perishing materials.
3M 1328 Alnox
- Contact not 100% which increases
resistance. - Loosing of joint over a period of time.
- Uneven pressure both in crimping as well as
a thimble. Pressure is more near bolt and less
as we approach edges. - Oxidation in copper and aluminum further
increases resistance.
Scotch Heavy Duty Mining Tape 31
- Cable outer jacket damage repair tape
- Highest abrasion resistance
- Moisture proof with built-in mastic
- Non-corrosive, synthetic rubber
- Self-healing flame retardant mastic
- Excellent aging properties
- MSHA approved
- 50 mm x 8.5 feet
Applications include :
- On-site quick cable jacket repair
- Protective layer for trailing cable to abrasion proof
- Repaired joints to be flexible