314*
- Moisture Resistant Seal
- Flame Retardant
- Maximum Insulation 0.155" (3,94)
- Wire Range 22-14 (0,5-1,5)
- Temperature 105*C (221*F)
314U
- Dry Environment Applications.
- Flame Retardant
- Maximum Insulation 0.155″ (3,94)
- Wire Range 22-14 (0,5-1,5)
- Temperature 105*C (221*F)
316 IR
- Moisture Resistant Applications
- Maximum Insulation 0.155″ (3,94)
- Wire Range 22-16 (0,5-1,5)
- Temperature 105*C (221*F)
3M “Performance Plus” connectors
Construction:
- Steel Spring
- Corrosion resistant coating
- Shell is made of Flame Retardant material.
- Wire Range (SQ MM): 0.75 sq mm to 10 sq mm
557*
- Dual Element Connection
- Flame Retardant
- Maximum Insulation 0.155″ (3,94)
- Wire Range 22-16 (0,5-1,5)
- Temperature 105*C (221*F)
558*
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Flame Retardant
- Maximum Insulation 0.155″ (3,94)
- Wire Range 22-16 (0,5-1,5)
- Temperature 105*C (221*F)
560
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 105*C (221*F)
560B
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 105*C (221*F
560N
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 105*C (221*F)
562
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Run & Tap Splicing Flame Retardant
- Maximum Insulation 0.190″ (4.82 mm)
- Wire Range 12-10 (3,0-4.0)
- Solid/Standard 10 standard
- Temperature 90*C (194*F)
564
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Dual Element Connection
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm) Tap
- Wire Range 18-14 (0,75-1,5)
- Temperature 90*C (194*F)
567
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Dual Element Connection
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm) Tap & 0.190" (4.82mm) Run
- Wire Range 18-14 (0,75-1,5) Tap & 12-10 (3.0-4.0) Run
- Temperature 105*C (221*F)
804
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Moisture Resistant Applications
- Flame Retardant
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Solid/Standard 14 standard
- Temperature 75*C (167*F)
901
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Disconnect
- Maximum Insulation 0.145″ (3,68mm)
- Wire Range 18-16 (0,75-1,5)
- Temperature 90*C (194*F)
905
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Low Voltage (Automotive) Applications
- Maximum Insulation 0.110" (2.79 mm) Tap & 0.145" (3.68 mm) Run
- Wire Range 22-18 (0.5-1.0) Tap & 18-14 (0.75-1.5) Run
- Temperature 90*C (194*F)
905N
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ Run & Tap Connectors
- Low Voltage (Automotive) Applications
- Maximum Insulation 0.110" (2.79 mm) Tap & 0.145" (3.68 mm) Run
- Wire Range 22-18 (0.5-1.0) Tap & 18-14 (0.75-1.5) Run
- Temperature 90*C (194*F)
951
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ T-Tap Disconnect Connectors
- Moisture Resistant Applications
- Maximum Insulation 0.150″ (3,81)
- Wire Range 22-18 (0,5-1,0)
- Temperature 105*C (221*F)
952
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ T-Tap Disconnect Connectors
- Moisture Resistant Applications
- Maximum Insulation 0.150″ (3,81)
- Wire Range 22-14 (0,75-1,5)
- Temperature 105*C (221*F
953
Connectors, Connectors, Connectors and Cable ties, Electrical, IDCS, Scotchlok™ T-Tap Disconnect Connectors
- Moisture Resistant Applications
- Maximum Insulation 0.150″ (3,81)
- Wire Range 12 (3,0)
- Temperature 105*C (221*F)
972-A
- Fuse Holder
- Maximum Insulation 0.150″ (3,81)
- Wire Range 18-14 (0.75-1.5)
- Temperature 105*C (221*F)